Analisis pengaruh filter karbon aktif alami pada air purifier Daikin MC30VVM-H terhadap kualitas udara

Fahmi Denta Pahlevi El Fanshury, Dafit Feriyanto

Abstract


Air pollution is the biggest environmental problem and has a direct impact on humans. Indoor air pollution also needs attention because humans spend a lot of time indoors. This study aims to determine the effect of natural carbon, namely coconut shell charcoal. In this study, the air purifier was placed in the room. The room will be given artificial pollution until the PM2.5 air quality gauge shows a number above 400 or more. Then the water purifier is turned on using auto mode and takes measurements of physical and chemical air quality parameters using a measuring instrument every 10 minutes 7 times. This research was conducted with a three variation experiment. Variation one is using a carbon filter that is already installed in the air purifier, variation two uses 100% natural carbon, and variation three is a combination of variations one and two. Where in this study analyzes the effect of air quality produced on the air purifier before and after installing the natural carbon filter. Based on the results of testing and data processing, the use of variation three on the water purifier filter is more effective than variation one and variation two.


Keywords


Air Quality; PM10; PM2.5; Air Purified; Natural Activated Carbon

Full Text:

PDF

References


WHO, “The cost of a polluted environment: 1.7 million child deaths a year, says WHO,” 2018

Tim Deutsche Welle (2020) Polusi Udara Tahun 2020 Tewaskan 98 Ribu Orang di Seluruh Dunia.

US Environmental Protect Agency. ).” Air quality criteria for particulate matter” 2004

Adrian.” Mengenal Sumber Polusi Udara di Dalam Rumah dan Cara Menguranginya,” 2021

Chaeroni. F, dan Marbun. P, “Manfaat Air Purifier, Benarkah Mampu Membunuh Virus Corona?,” 2020

Fardiaz, S. ,”Polusi air & udara” Yogyakarta: Kanisius, 1992

Peraturan Menteri Kesehatan Republik Indonesia Nomor 1077 Tahun 2011

Ir. Sarsinta. “Suhu,” 2008

Saripudin, A., D. Rustiawan K., dan A. Suganda,”Praktis Belajar Fisika” 2009

Rutledge ‘ “Humidity,” 2011

Achmadi; ‘”hygrometer” dan jenisnya” 2019

Santoso. “ Kelembaban” 2007

Lawson et.al 1990

Anderson, L. G., Lanning, J. A., Barrell, R., Miyagishima, J., Jones, R. H. & Wolfe, P. (1996). “Sources and sinks of formaldehyde and acetaldehyde: An analysis of Denver‟s ambient concentration data‟, Atoms. Environ. 30, 2113–2123.


Refbacks

  • There are currently no refbacks.


Copyright (c) 2022 Journal of New Energies and Manufacturing

INDEXED IN


Publisher Address:
Universitas Mercu Buana
Program Studi Teknik Mesin
Jl. Meruya Selatan No. 1, Jakarta 11650, Indonesia
Phone/Fax. (+6221) 5871335
Email [email protected]
Homepage http://teknikmesin.ft.mercubuana.ac.id/

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.