Analisis PHE (Potensi Hemat Energi) dan Pengembangan Software Efisiensi Energi Pada Rumah Sakit Ba, Tangerang
DOI:
https://doi.org/10.22441/jtm.v7i3.5255Keywords:
Potensi Hemat Energi (PHE), Intensitas Konsumsi Energi (IKE), audit energi, Visual Studio, Efisiensi Energi Rumah SakitAbstract
Abstrak. Sampai saat ini, 95% dari kebutuhan energi nasional masih dipenuhi energi fosil, sementara kontribusi energi terbarukan baru mencapai 5%. Indonesia masih tergolong boros dalam menggunakan energi yang ditunjukan dari nilai intensitas energi yang masih tinggi. Salah satu cara pengurangan energi gedung adalah dengan efisiensi dan audit energi di Gedung tersebut. Penelitian ini dilakukan di Gedung Rumah Sakit BA, Tangerang. Tujuan dari penelitian ini adalah untuk menentukan IKE (Intensitas Konsumsi Energi), analisis potensi hemat energy, dan serta pengembangan software untuk perhitungan dan evaluasi penggunaan energy di Gedung Rumah Sakit BA. Metode yang digunakan adalah metode analisis deskriptif kuantitatif dengan memeriksa nilai IKE dan membandingkan secara umum kondisi konsumsi energy gedung tersebut dengan nilai standar pemerintah. Alat yang digunakan dalam penelitian adalah Environment meter, multimeter dan Tang ampere. Pengolahan data ini dilakukan dengan membuat aplikasi perangkat lunak, menggunakan program Visual Studio yang terkoneksi dengan Microsoft access sebagai penyimpan data. Dari hasil penelitian, didapatkan nilai Intensitas konsumsi energi (IKE) pada Gedung Rumah Sakit BA sebesar 23.73 kWh/m2/Bulan atau 284.076 kWh/m2/Tahun. Dengan menggunakan rujukan ASEAN USAID 1992, nilai ini masuk dalam kategori efisien, karena untuk IKE standarisasi gedung rumah sakit yaitu 380 kWh/m2/Tahun. Kondisi lampu penerangan masih menggunakan lampu TL dengan daya 36 watt dengan menggunakan armature jenis lama, sehingga pencahayaan kurang efisien. Kondisi AC split secara umum kinerjanya bisa dikatakan kurang efisien karena masih menggunakan freon jenis R22 yang tidak ramah lingkungan, boros dan masih banyak ruangan terbuka, sehingga menimbulkan potensi kerugian energy karena terbuang percuma. Dengan menganalisis potensi hemat energy, dan berbiaya rendah, maka, pengeluaran dapat dihemat hingga 30% dari total penggunaan energy selama satu tahun. Sedangkan dengan menggunakan aplikasi program hemat energy, maka tampilan dengan tampilan menarik dan handal, dapat memudahkan pemakai untuk mencari nilai IKE, mencari nilai Kwh dan biaya energy yang dipakai di gedung tersebut. Hasil perhitungan tersebut dapat disimpan, dicari dan dipanggil kembali saat sewaktu waktu diperlukan.Downloads
Downloads
Published
How to Cite
Issue
Section
License
The copyright to this article is transferred to Universitas Mercu Buana (UMB) if and when the article is accepted for publication. The undersigned hereby transfers any and all rights in and to the paper including without limitation all copyrights to UMB. The undersigned hereby represents and warrants that the paper is original and that he/she is the author of the paper, except for material that is clearly identified as to its original source, with permission notices from the copyright owners where required. The undersigned represents that he/she has the power and authority to make and execute this assignment.
We declare that:
1. This paper has not been published in the same form elsewhere.
2. It will not be submitted anywhere else for publication prior to acceptance/rejection by this Journal.
3. A copyright permission is obtained for materials published elsewhere and which require this permission for reproduction.
Furthermore, I/We hereby transfer the unlimited rights of publication of the above mentioned paper in whole to UMB. The copyright transfer covers the exclusive right to reproduce and distribute the article, including reprints, translations, photographic reproductions, microform, electronic form (offline, online) or any other reproductions of similar nature.
The corresponding author signs for and accepts responsibility for releasing this material on behalf of any and all co-authors. This agreement is to be signed by at least one of the authors who have obtained the assent of the co-author(s) where applicable. After submission of this agreement signed by the corresponding author, changes of authorship or in the order of the authors listed will not be accepted.
Retained Rights/Terms and Conditions
1. Authors retain all proprietary rights in any process, procedure, or article of manufacture described in the Work.
2. Authors may reproduce or authorize others to reproduce the Work or derivative works for the authors personal use or for company use, provided that the source and the UMB copyright notice are indicated, the copies are not used in any way that implies UMB endorsement of a product or service of any employer, and the copies themselves are not offered for sale.
3. Although authors are permitted to re-use all or portions of the Work in other works, this does not include granting third-party requests for reprinting, republishing, or other types of re-use.
This work is also licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.