APLIKASI 6 SIGMA DALAM MENURUNKAN MALFUNCTION DEFECT DI PENGETESAN ELEKTRIKAL (AC TRANSIENT TEST) PADA TAHAPAN PENGEMBANGAN PRODUK BLU-RAY DISC PLAYER (STUDI KASUS DI PERUSAHAAN MANUFAKTUR ELEKTRONIK)

Dony Arief Widiatmoko, Waseso Segoro

Abstract


Abstract. The research helds inelectrical product manufacturing company, focus of the
product is Blu-ray Disc Player. The dominant problem caused by electrical test at the product
development process is Malfunction at AC Transient test where contribution is 83% from
total electrical problem. Main objectives of this research are to determine the vital factors and
provide optimal solution to reduce/elimate these problem at development stage. The problem
solving methodology using Six Sigma DMAIC and DOE .The analysis indicated that line
filter value and spark gap distance in the PCB SMPS are vital factors that influence the
malfunction defective as AC Transient test result. The design of experiment (DOE) technique
use to define the optimum values of vital factor‟s needed to reduce/eliminate the defect. As a
result, a reduction of malfunction defective at AC Transient test was achieved, from 125000
ppm to 0 ppm and thus improve its Sigma level from 2.65 to 6.
Keywords:Defective reduction, DMAIC, DOE, malfunction defective, AC Transient test.

Full Text:

PDF

Refbacks

  • There are currently no refbacks.


MIX: Jurnal Ilmiah Manajemen
Journal URL: http://publikasi.mercubuana.ac.id/index.php/Jurnal_Mix
Journal DOI: 10.22441/jurnal_mix
P-ISSN: 2088-1231
E-ISSN: 2460-5328

Editor's Address:

Magister Management Department, Universitas Mercu Buana.
Tedja Buana Building 4th Floor.
Jl. Menteng Raya No. 29, Jakarta 10340.

The Journal is Indexed and Abstracting by:

 

Web
Analytics Made Easy - StatCounter
View My Stats