simulated case method. The potential for fire and explosion or the value of the Fire Explosion Index (F&EI) in the simulated case is 111,24. The actual exposure radius is 29.62 m and the damage factor to the Pertamax storage tank is 63%. The results of the study have a risk level that is classified as Intermediate, so it is necessary to control risks such as increasing active protection and is expected to be an input in efforts to safeguard against non-military threats so as to reduce the impact of risks and losses that occur in the Pertamax storage tank.
Keywords
Full Text:
PDFReferences
American Institut Of Chemical Engineers. (1994). Dow's Fire And Explosion Index Hazard Classification Guide, 7th Edition. New York: American Institute Of Chemical Engineers
Dulpi, M. (2008). (Thesis) Analisa Resiko Kenakaran Terkait Dengan Kegagalan Peralatan Pada Kegiatan Pembongkaran dan Penyaluran BBM Di SPBU "X".
Furness, A., & Muckett, M. (2007). Introduction to Fire Safety Management. United Kingdom: Elsevier.
Indrawan, Jerry. 2016. Ancaman Non-Militer Terhadap Keamanan Nasional di Papua. Jurnal Ilmiah Hubungan Internasional. Vol 12 No. 02.
PT. Pertamina (Persero). (2007, Juni). Material Safety Data Sheet (MSDS) Pertamax.
Setyawan, H., Suwondo, A., & Setyaningsih, Y. (2016, Desember 1). Praktik Keselamatan Kebakaran pada Operator SPBU di Kabupaten Blora. Promosi Kesehatan Indonesia, 8(No.1), 17-29.
Ramli, S. (2010). Petunjuk Praktis Manajemen Kebakaran (Fire Management). Jakarta: Dian Rakyat.
Suardin, J. (2005). The Integration of Dow's Fire and Explosion Index into Process Design and Optimization to Achieve an Inherently Safer Design Master of Science. Texas: Texas A&M University
PT. Pertamina (Persero). (2007, Juni). Material Safety Data Sheet (MSDS) Pertamax.
DOI: http://dx.doi.org/10.22441/ijimeam.v3i3.13986
Refbacks
- There are currently no refbacks.
Copyright (c) 2022 Rizky Aferdiansyah, Novita Affuwani, Mas Ayu Elita Hafizah, Robertus Heru Triharjanto, Widianto Nugroho
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
INDEXED IN
Publisher Address:
Universitas Mercu Buana
Program Studi S2 Teknik Mesin
Jl. Meruya Selatan No. 1, Jakarta 11650, Indonesia
Phone/Fax. (+6221) 5871335
Email [email protected]
Homepage http://teknikmesin.ft.mercubuana.ac.id/
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.